Description
Victron Energy galvanic isolator, rated 32 amps. A step up from the VDI-16; for a 50 amp shore power service, see the VDI-64.
It blocks the low-voltage DC current that enters the boat through the shore power earth wire, which causes electrolytic corrosion of underwater metal such as the hull, propeller and shaft, while still passing AC safety ground current. Inside are two diodes in anti-parallel; they only conduct above about 1.4 V DC.
Installation
- Wire it into the green (safety) ground ahead of every ground connection on the boat, so nothing bypasses it
- Mount it vertically (long side up) in a well-ventilated spot with 4″ (10 cm) of clear space around it; the heat sink can get hot while carrying fault current
Specifications
- Maximum current: 32 A
- Peak current (20 ms): 3,200 A
- Construction: waterproof (potted), IP67, anodized aluminium heat sink
- Connections: M6 studs
- Dimensions: 2.5″ H x 6.5″ W x 7.9″ D (63 x 164 x 200 mm)
- Weight: 4.4 lb (2 kg)
See how this compares to our other galvanic isolators (16A–64A)